PRODUCTION TYPE

 

:

Modular Construction with GALVANIZED trapezoidal sectioned metal sheet body.
Type-1 Containers are manufactured with the sizes of 2.40X6.00X2.60 m and
Type-2 Containers are manufactured with the sizes of size of 3.00x7.00x2.60 m. Apprx.weight of containers for Type-1 is 2.40X6.00:1500 kg, and Type-2 is 3.00x7.00:2500 kg. All materials certificated by TSE.

TECHNICAL DATAS

:

Snow Load

80 kg/m²

Wind Velocity

102 km/h

External Wall Heat Transmission Coefficient

K: 0.74 Kcal/m²hC

Internal Wall Heat Transmission Coefficient

K: 0.69 Kcal/m²hC

Roof Heat Transmission Coefficient

K: 0.68 Kcal/m²hC

Floor Heat Transmission Coefficient

K:3.85 Kcal/m²hC

Base-Plate(chassis) Load Capacity

200 kg/m² ( Calculated in accordance withT.S 498 )

EXTERNAL WALLS

:

External Wall Height

2600 mm

Internal Clear Height

2320 mm

Outer Surface Covering

30 mm roll depth, 0.50 mm thick filmed covered,RAL 9002 furnace painted GALVANIZED trapezoidal sectioned steel sheets.

Insulation

40 mm thick expanded polystrene foam.(10/12 kg/m³)

Internal Surface

PVC Panelling. (If required 8mm thick,white colored, non-combustible ,FIBERCEMENTboard-Hekimboard brandmarked DIN 4102-2 A2 class )

INTERNAL WALLS

:

Internal Wall Height

2320 mm

Surface Covering

PVC Panelling. (If required 8mm thick,white colored, non-combustible ,FIBERCEMENTboard-Hekimboard brandmarked DIN 4102-2 A2 class )

Insulation

40 mm thick expanded polystrene foam.(10/12 kg/m³)

FLOOR COVERING

:

Construction

Construction comprised of horizontal profiles

Covering

Vinyl Tile (300x300x1.6mm foil covered) as floor covering on the 16mm thick, non-combustible, FIBER CEMENT board-Hekimboard brandmarked DIN 4102-2 A2 class and in wet volumes 20x20 ceramics tiles.

Insulation (OPTIONAL)

0.50 mm thick natural galvanized trapezoidal sectioned steel sheet over the construction that comprised of horizantal profiles+20 mm thick expanded polystrene foam(10-12 kg/m3) +16 mm thick,non-combustible, FIBER CEMENT board-Hekimboard brandmarked DIN 4102-2 A2 class + vinyl tile (300x300x1.6mm foil covered) and in wet volumes 20x20 ceramics tiles.Floor Heat Transmission Coefficient:K:1.19 Kcal/m2hC

CEILING COVERING

:

Covering

PVC Panelling. (If required 8mm thick,white colored, non-combustible ,FIBERCEMENTboard-Hekimboard brandmarked DIN 4102-2 A2 class )

ROOF

:

Roof Construction

U shaped outer frame, bearing box profiles (Rain water will be discharged by 4 corners columns of the container.)

Covering

27 mmx200 mm roll depth, 0.50 mm thick galvanized trapezoidal sectioned unpainted steel sheets

Insulation

80 mm mattress glass wool (14 kg/m3)

DOOR JOINERIES

:

External Doors
(1,2 mm thick DKP steel sheet framed+
0,50 mm thick furnace painted steel sheet )

860/1960 mm insulated steel sheet door (outer size). Expanded polystrene foam insulation in between 0,50 mm thick, RAL 9002 painted, film covered, galvanized steel sheets, Leaf thickness :45 mm. Special formed door frames with rubber gasket.

Internal Doors
(1,2 mm DKP steel sheet framed)

840/1960 mm Mdf-slide Press door (outer size), Leaf thickness :42 mm

Wet Volume Doors
(1,5 mm thick DKP steel sheet framed )

620x1960 mm mdf-slide (outer size),Leaf thickness :42 mm

Door Lock and Handle

External doors have cylindirical ,internal doors have encased locks with yellow or grey coloured metal door hadles.

WINDOW JOINIRIES

:

Window (1.5 mm thick DKP steel sheet framed+ 0,50 mm thick furnace painted steel sheet )

1000/1170 mm PVC with PVC handles

Kitchen-wc-shower area

Dia 200 mm electrical, kitchen-type extractor fan with lid.

GLASS

:

Single Glazing

4 mm

Double Glazing

4+9+4 mm (OPTIONAL)

PAINT

 

Outer Facade, external door and window frames

Galvanized steel sheets with RAL 9002 (Broken White Color) furnace painted.

Internal Door Frames

1 layer rapid primer + 1 layer semi- synthetic oily based paint - Black in color.Brandmark:HEKİM ,

Outer Corners

1 layer rapid primer + 1 layer semi- synthetic oily based paint - will be applied with special membraned dust painting tools. BELT COLORS: RAL 3020 Kırmızı or RAL 5022 DARK BLUE Brandmark HEKİM

Other metal parts (base plate(chassis),bearing construction )

1 layer rapid Primer - Brandmark :HEKİM



ELECTRICAL and PHONE INSTALLATION

(Under the plaster)

( The installation will be done over the plaster in case of using FIBER CEMENT boards or chipboard as internal coverings )

:

Cabling

(2000 Watt,220 Volt),
Socket Cables 3X2.5 mm² NYM, Lighting Cables 2x1.5 mm² NYM

Lighting Armatures

Usual Areas

Round Type Armatures

Wet volume, Over exit door

Globe -IP 44

Electrical Sockets,switch

Appropriate number will be supplied in accordance with the plan

Fuses and fuses boxes

Appropriate number will be supplied in accordance with the plan

Phone sockets

Appropriate number will be supplied in accordance with the plan

SANITARY INSTALLATION  : (Under the plaster) ( The installation will be done over the plaster in case of using FIBER CEMENT boards or chipboard as internal coverings)

Vitreous / Armatures

Lavatory/Washbasin

37x45 cm Wall type

Lavatory and shower taps

Taps are wall mounted in cold water installation lavatories and taps have outlets from lavatories in hot water installation lavatories.

Water Closet

Western style water closetwith WC taps. Plastic flushing cistern

Shower Tray

76 cmx76 cm Polyester

Kitchen Sink

Chromium-plated 50/100 cm double, lower chipboard cupboard. No cupboard above the sink.

Accessories

PVC Paper holder, soap dish, mirror, shelf, closet lid.

Pipes

Clean water

PPRC

Waste water

PVC


LIFTING SYSTEM

 

The loading and unloading facility shall be made by connecting the steel ropes lying in the same interval to the iron Lifting eyes mounted hiddenly on the corners, to the lockers. If required the containers shall be two or multi-storied. The transport system of all containers will be organized by concerning that specification. WC, Shower containers will be produced with insulation or without any insulation