PRODUCTION TYPE

Side walls framed with box profiles,upper and lower chassis are connect to each other by using special formed U profiles and galvanized covered bolted system,side,upper and lower lids are mounted by using special bolted system. One container is comprised of six pieces.

Modular Construction with GALVANIZED trapezoidal sectioned metal sheet body.

Type-1 Containers are manufactured with the sizes of 2.40X6.00X2.60 m and

Type-2 Containers are manufactured with the sizes of size of 3.00x7.00x2.60 m.

Apprx.weight of containers for Type-1 is 2.40X6.00:2000 kg, and

Type-2 is 3.00x7.00:2800 kg. All materials certificated by TSE.

TECHNICAL DATAS

Snow Load

:

80 kg/m²

Wind Velocity

:

102 km/h

External Wall Heat Transmission Coefficient

:

K: 0.38 Kcal/m²hC

Internal Wall Heat Transmission Coefficient

:

K: 0.60 Kcal/m²hC

Roof Heat Transmission Coefficient

:

K: 0.38 Kcal/m²hC

Floor Heat Transmission Coefficient

:

K:0.38 Kcal/m²hC

Base-Plate(chassis) Load Capacity

:

200 kg/m²
( Calculated in accordance with
TS 498 )

EXTERNAL WALLS

External Wall Height

:

2600 mm

Internal Clear Height

:

2345 mm

Outer Surface Covering

:

30 mm roll depth, 0.75 mm thick,RAL 9002 electrostatic powder painted galvanized trapezoidal sectioned steel sheets.

Insulation

:

60 mm thick expanded polystrene foam
(10/12 kg/m³)+
average 80 mm thickexpanded polystrene foam insulation with trapezoidal gaps.

Internal Surface

:

10 mm thick, non-combustible , FIBERCEMENT board- Hekimboard brandmarked
DIN 4102-2 A2 class

INTERNAL WALLS

Internal Wall Height

:

2345 mm

Surface Covering

:

10 mm thick, non-combustible , FIBERCEMENT board- Hekimboard brandmarked DIN 4102-2 A2 class

Insulation

:

40 mm thick expanded polystrene foam
(10/12 kg/m³)

Carcase

:

Comprised of box profiles and special formed U profiles

FLOOR COVERING

Construction

:

Construction comprised of horizontal profiles+0.50 mm thick unpainted galvanized trapezoidal sectioned steel sheets

Insulation

:

80 mm thick expanded polystrene foam
(10/12 kg/m³)

Covering

:

3 mm thick PVC roll as floor covering on the
16 mm
thick, non-combustible, FIBER CEMENT board-Hekimboard brandmarked
DIN 4102-2 A2 class

CEILING COVERING

Covering

:

10 mm thick, non-combustible , FIBERCEMENTboard- Hekimboard brandmarked DIN 4102-2 A2 class

ROOF

Roof Construction

:

Comprised of U shaped outer frame, bearing box profiles and galvanized eave (Rain water will be discharged by 4 corners columns of the container.)

Covering

:

27 mmx200 mm roll depth, 0.50 mm thick unpainted galvanized trapezoidal sectioned steel sheets

Insulation

:

80 mm mattress glass wool (14 kg/m3)

DOOR JOINERIES

External Doors
(1,2 mm thick galvanized steel sheet frame)

 

:


860/1960 mm insulated steel sheet door (outer size)Comprised of expanded polystrene foam insulation(10-12 kg/m3) and 0,75 mm thick ,RAL 9002 painted galvanized steel sheets over 4 mm thick wooden chipboard. Leaf thickness : 45 mm. Special formed door frames with rubber gasket.

 

Internal Doors
( 1,2 mm thick galvanized steel sheet frame)

:

840/1960 mm Mdf-slide Press door (outer size), Leaf thickness :42 mm

Wet Volume Doors (1,2 mm thick galvanized steel sheet frame )

:

620x1960 mm mdf-slide (outer size),Leaf thickness :42 mm

Door Lock and Handle

:

External doors have cylindirical ,internal doors have encased locks with yellow or grey coloured metal door hadles.

WINDOW JOINIRIES

Window (1.2mm galvanized thick steel sheet frame)

:

890/1190 mm PVC with PVC handles

Kitchen-wc-shower area

:

Dia 100 - 120 mm electrical, kitchen-type extractor fan with lid.

GLASS

Single Glazing

:

4 mm

Double Glazing

:

4+9+4 mm (OPTIONAL)

PAINT

Outer Facade,l door and window frames

:

RAL 9002 (Broken White) colored, electrostatic powder painted. No painting is required for chipboards.

Inner Facade

:

Non-combustible FIBERCEMENT, boards(Hekimboard brandmarked DIN 4102-2 A2 class) are colored with 2 layers of plastic paintings. Brandmark:HEKİM

Outer Corners

:

1 layer rapid primer + 1 layer semi- synthetic oily based paint - will be applied with special membraned dust painting tools. BELT COLORS: RAL 3020 Kırmızı or RAL 5022 DARK BLUE BrandmarkHEKİM

Other metal parts (base plate(chassis),bearing
construction )

:

1 layer rapid Primer - Brandmark :HEKİM

ELECTRICAL and PHONE INSTALLATION
(Over the plaster)

Cabling :

 

(2000 Watt,220 Volt),

Socket Cables 3X2.5 mm² NYM,

Lighting Cables 2x1.5 mm² NYM

Lighting Armatures:

Usual Areas

Round Type Armatures

Wet volume,

Over exit door

Globe -IP 44

Electrical Sockets,switch:

Appropriate number will be supplied in accordance with the plan

Fuses and fuses boxes:

Appropriate number will be supplied in accordance with the plan

Phone sockets :

Appropriate number will be supplied in accordance with the plan

SANITARY INSTALLATION
(Over the plaster)

Vitreous / Armatures

:

Lavatory/Washbasin

37x45 cm Wall type

Lavatory and shower taps

Taps are wall mounted in cold water installation lavatories and taps have outlets from lavatories in hot water installation lavatories.

Water Closet

Western style water closetwith WC taps. Plastic flushing cistern

Shower Tray

76 cmx76 cm Polyester

Kitchen Sink

Chromium-plated 50/100 cm double, lower chipboard cupboard.No cupboard above the sink.

Accessories

Chromium-plated Paper holder,soap dish,chromium framed mirror, glass shelf, closet lid.

Pipes          :

Clean water

PPRC

Waste water

PVC

LIFTING SYSTEM

The loading and unloading facility shall be made by connecting the steel ropes lying in the same interval to the iron Lifting eyes mounted hiddenly on the corners, to the lockers. If required the containers shall be two or multi-storied. The transport system of all containers will be organized by concerning that specification.

The technical specifications are subject to any modification made by Prefabrik Yapı Cons. Ind. & Trade Ltd. Co.

Modular System Container Plans are Valid